High voltage single-ended probe

ETA5239V Oscilloscope high voltage probe

ETA5239V can measure up to 39KV DC, 27KV AC voltage, 900MΩ input impedance, low load effect, and 50MHz bandwidth allows you to capture fast, high-voltage signals. The high-voltage probe can be directly connected to the oscilloscope for direct measurement, suitable for the measurement of the high-voltage ground reference voltage. In addition, the voltage value can be measured on the digital meter by purchasing an adapter. The body of ETA5239V is filled with inert gas, which can increase the insulation performance, measure high voltage and ensure that the internal components will not oxidize and extend the service life.

Features:
• Maximum measurement voltage: 39KV DC+ACpeak
• Bandwidth up to 50MHz
• Input impedance 900MΩ
• Fixed attenuation ratio 1000:1
• With impedance matching device, it can be connected to a multimeter for use
• Ultra low noise




ModelETA5239V
Attenuation ratio1000:1
Read function-
Input resistance900MΩ
Input capacitance2.0PF
Maximum input:DC+AC peak39KV CAT II
Maximum input:AC RMS27KV CAT II
Pulse voltage<27KVp-p
Maximum load current45uA
bandwidthDC~50MHz
Rise Time7nS
Noise ratio>60dB at 1KHz ; >50dB at 1MHz
DC signal error value≤3% of the entire range, ≤3% (0-35KV)
AC signal error value≤3% 在1KHz
Temperature Coefficient≤200 PPM/℃
Matching capacitance adjustment range10PF~35PF
Safety inspectionComply with EN61010-031 CAT II specification
Length of test line2M±0.2M
Working temperature and humidity0~40℃,80% or less
Storage temperature and humidity-10~45℃,80% or less
Color: grip/bodyBlack/red
Size80mmx80mmX320mm
Weight460g

* All parameters are from the ETA manufacturer, if there is any change, please refer to the actual product and the manufacturer’s instructions