Current measuring probe

ETA5314 Series oscilloscopes with high frequency current loops

ETA5314 series current sensor is used for AC current measurement, the measured current is up to 400A RMS, the maximum pulse current is 100KA, the bandwidth is 2MHZ, the rise time is 200ns, and the jaw diameter is about 50mm; Standard BNC output interface, can be connected to any manufacturer oscilloscope; Add standard accessory BNC to banana socket to realize the connection to the digital multimeter. Widely used in high-end medical multi-band current sensing; Square wave, triangle wave passive mutual inductance, laboratory broadband current research, lightning surge waveform observation, switch short-circuit current detection.

ModelETA5314ETA5314A
Bandwidth Hz10Hz~2MHz
Rise time≤200ns
Enter the typeAC
precision士1%
Current conversion ratio1mV/A
Minimum RMS400A50mA
Maximum RMS20KA200A

Maximum pulse peak electricity

200A100KA
Jaw diameter∅50mm

Oscilloscope input impedance

1MΩ
Interface typeBNC
Cable length100cm
Accessories are standard 4mm adapter plug
Size134.6X 108X32mm127.8X100X26mm
Weight720g520g
Working environment-20~80°C, less than 80%RH

ETA5314.jpg

No video