| Model | ETA5301M |
| Range | 10A 100A |
| Current range | 100mA...10A peak 500mA...40A peak 40A...100A peak |
| Signal output accuracy | 3%士50mA 4%士50mA 15% |
| Phase shift | ≤ 1.5° |
| Current range 100mV/A | 7A AC 10A DC |
| Current range 10mV/A | 70A AC 100A DC |
| Typical frequency response curve | Please refer to the image on the right. |
| Measuring current range | 50mA~100A peak |
| Maximum working voltage | 600V CATⅢ |
| Frequency range | DC to 500KHz (-3dB) |
| Typical battery types and their lifespan | 9V NEDA1604A, IEC6LR61 (55小时) |
| Typical DC signal linear | Please refer to the image on the right. |
| Typical phase shift | Please refer to the image on the right. |
| Jaw size | Maximum 13mm |
| Overall dimensions | Control box: 109mm x 24.2mm x 57.8 mm, current clamp: 102.6 mm x 24.5mm x 54.6 mm |
| Cable length | Length of the cable from the control box to the BNC connector: 1.3m; Length of the cable from the control box to the current clamp: 1.0m |
| Operating temperature | 0 ℃ to + 50 ℃ |
| Humidity | 95% RH or less (at 0~40 ℃) |
| Safety regulations | Meets EN61010-1/A2:1995 Meets EN61010-2-032:1995 |