Knowledge

Can AC current probe measure DC?

admin 2026-11-25 14:45:04 0次

Core conclusion: pure AC probe can not measure DC, AC and DC dual-purpose Hall probe to support DC measurement.

02

一、Pure AC current probe (Rogowith coil/ordinary AC clamp probe)

Measurement principle: Faraday's law of electromagnetic induction

The output induced voltage depends only on the rate of change of current \(\boldsymbol{di/dt}\)

1. The DC current is constant,\(di/dt = 0\), the probe has no output signal, and the oscilloscope cannot collect the DC component;

2. Only AC ripple and alternating pulse signal can be collected;

3. A large DC current will cause magnetic saturation of the iron core, causing AC waveform distortion and amplitude misalignment.

Typical category: passive Rogowell coil, unbiased AC clamp current probe

Not suitable for measuring DC, current signals with DC bias.

二、AC/DC current probe (Hall current probe)

Built-in Hall sensor, can directly sense the constant magnetic field:

1. At the same time support DC steady-state current, AC ripple acquisition;

2. Self-contained magnetic field compensation circuit to avoid DC magnetization saturation problem;

3. The oscilloscope can completely restore the DC/AC superimposed waveform and adapt to the test scenarios such as the output current of the switching power supply and the bus current of the motor.

Quickly distinguish between the two probes

- Identification: label AC/DC Current Probe → support DC; label AC only → AC only

- Power supply identification: Hall probe generally needs external power supply or oscilloscope interface power supply; Rogowell coil is passive structure, no power supply

04

三、Common Mistakes in Field Testing

1. Rogowell coil measures the bus current of the switching power supply: only the switch ripple can be observed, and the DC average current cannot be measured;

2. AC probe carrying large DC: iron core magnetic saturation, AC waveform distortion, low measurement value;

3. If it is necessary to observe DC mean value and AC fluctuation at the same time: Hall AC/DC probe is preferred.

Key Points Shorthand

AC probe (Rogowell coil): only AC is measured, DC is not measured

Hall AC/DC probe: AC and DC can be measured