| Specifications | |
| Measuring range | 30A/300A/3000A AC |
| Output accuracy | 100mV/10mV/1mV per (AC coupled) |
| Error (45~65Hz) | ±1% of reading ±0.1A 30/300A range ±1% of reading ±1A 3000A range |
| Minimum load | 100KΩ for specified accuracy |
| Frequency range | 10Hz...20KHz(-1dB) |
| Phase (45~65Hz) | <±1。 |
| Position sensitivity | ±2% of reading |
| Outfield | ±0.2% of reading with cable>200mm(8") from the probe |
| Noise | 8mV rms in 30A range 2mv rms in 300A/3000A ranges |
| Temperature coefficient | ±0.1% of reading/ ℃ |
| Power Supply | Two AA mn1500 LR6 alkaline batteries,or an external power supply (+3V/100mA) |
| Battery life | 2000 hours typical value |
| External power supply | Through 2.1mm mini power connector (Out-of-factory non-provision) |
| Low power | Orange LED indication |
| Overrange | Red LED indication |
| Attachment | |
| Material | ARNITE T06-200SNF,UL94 V0 |
| Protection level | ip40 |
| Size | 110(L)×65(W)×23(d)mm |
| Output | 0.5m coax cable terminated with a safety bnc |
| Material | Alcryn 2070NC,LATI LATENE 7H2W V0 |
| Protection level | IP65 |
| General characteristics | |
| Operating temperature | -20~65℃ |
| Storage temperature | -40~75℃ |
| Operating humidity | 10%-85%RH |
| Safety standards | EN61010-1 EN61010-2-032 |
| EMC | EN61326-2-2 |