Specifications | |
Measuring range | 30A/300A/3000A AC |
Output accuracy | 100mV/10mV/1mV per (AC coupled) |
Error (45~65Hz) | ±1% of reading ±0.1A 30/300A range ±1% of reading ±1A 3000A range |
Minimum load | 100KΩ for specified accuracy |
Frequency range | 10Hz...20KHz(-1dB) |
Phase (45~65Hz) | <±1。 |
Position sensitivity | ±2% of reading |
Outfield | ±0.2% of reading with cable>200mm(8") from the probe |
Noise | 8mV rms in 30A range 2mv rms in 300A/3000A ranges |
Temperature coefficient | ±0.1% of reading/ ℃ |
Power Supply | Two AA mn1500 LR6 alkaline batteries,or an external power supply (+3V/100mA) |
Battery life | 2000 hours typical value |
External power supply | Through 2.1mm mini power connector (Out-of-factory non-provision) |
Low power | Orange LED indication |
Overrange | Red LED indication |
Attachment | |
Material | ARNITE T06-200SNF,UL94 V0 |
Protection level | ip40 |
Size | 110(L)×65(W)×23(d)mm |
Output | 0.5m coax cable terminated with a safety bnc |
Material | Alcryn 2070NC,LATI LATENE 7H2W V0 |
Protection level | IP65 |
General characteristics | |
Operating temperature | -20~65℃ |
Storage temperature | -40~75℃ |
Operating humidity | 10%-85%RH |
Safety standards | EN61010-1 EN61010-2-032 |
EMC | EN61326-2-2 |