ETA5302B:1mV/A (2000A Max.Peak) | |||
Current range | 20A...50A | 50A...200A | 200A...2000A |
Signal output accuracy% | 1%+1mV | 2%+1mV | 2%+1mV |
Phase degree | 3° | 2° | 1° |
ETA5302B:10mV/A (200A Max.Peak) | |||
Current range | 10A...20A | 20A...50A | 50A...200A |
Signal output accuracy% | 2%+5mV | 3%+5mV | 3%+5mV |
Phase degree | 15° | 10° | 5° |
ETA5302B:100mV/A (20A Max.Peak) | |||
Current range | 1A...5A | 5A...10A | 10A...20A |
Signal output accuracy% | Not specified | 3%+10mV | 5%+10mV |
Phase degree | Not specified | Not specified | 15° |
Current range | 20A...2000A Peak 10A...200A Peak 5A...20A Peak |
Input/output ratio | 1mV~/1A~ 10mV~/1A~ 100mV~/1A~ |
Measuring current range | 5A~2000A Peak |
Maximum working voltage | 600V CATⅢ |
Frequency range | DC to 100KHz (-3dB for 50KHz to 100KHz) |
Jaw size | 100mm Max |
Overall dimensions | 216 x 11 x 45mm |
Cable length | 1.5米 |
Operating temperature | 0 ℃ to + 50 ℃ |
Humidity | 95% RH or less (at 0~40 ℃) |
Safety regulations | Meets EN61010-1/A2:1995 Meets EN61010-2-032:1995 |